=====================================================================Acq. Operator : CYL(HPLC-09) Seq. Line : 21Acq. Instrument : Instrument 1 Location : Vial 56Injection Date : 11/3/2015 3:03:09 PM Inj : 1 Inj Volume : 2.000 µlAcq. Method : D:\\CHEM32\\DATA\\20151103\\20151103 2015-11-03 07-54-29\\HM-385_11-H01P,CD,C2.MLast changed : 10/22/2015 4:49:15 PM by CYL(HPLC-09)Analysis Method : D:\\CHEM32\\METHODS\\RP-HPLC\\10-80A(210NM).MLast changed : 11/3/2015 3:28:45 PM by GTT(HPLC-09) (modified after loading)Catalog No : HY-13736A Batch#18386 A-RP-141 Additional Info : Peak(s) manually integrated VWD1 A, Wavelength=210 nm (D:\\CHEM32\\DATA\\20151103\\20151103 2015-11-03 07-54-29\\056-2101.D)mAU125010007505002500-25005101520min 5.482 4.386
===================================================================== Area Percent Report =====================================================================
Sorted By : Signal
Multiplier: : 1.0000Dilution: : 1.0000Use Multiplier & Dilution Factor with ISTDs
Signal 1: VWD1 A, Wavelength=210 nm
Peak RetTime Type Width Area Height Area # [min] [min] [mAU*s] [mAU] %
----|-------|----|-------|----------|----------|--------| 1 4.386 BB 0.0823 4202.89307 786.66760 99.7794 2 5.482 BB 0.0625 9.29403 2.28428 0.2206
Totals : 4212.18710 788.95189
===================================================================== *** End of Report ***
Instrument 1 11/3/2015 3:29:08 PM GTT(HPLC-09)Page 1 of 1
Data File D:\\CHEM32\\DATA\\20151103\\20151103 2015-11-03 07-54-29\\001-2001.DSample Name: WHQ2975-011-2G_0
=====================================================================Acq. Operator : CYL(HPLC-09) Seq. Line : 20Acq. Instrument : Instrument 1 Location : Vial 1Injection Date : 11/3/2015 2:38:45 PM Inj : 1 Inj Volume : 2.000 µlAcq. Method : D:\\CHEM32\\DATA\\20151103\\20151103 2015-11-03 07-54-29\\HM-385_11-H01P,CD,C2.MLast changed : 10/22/2015 4:49:15 PM by CYL(HPLC-09)Analysis Method : D:\\CHEM32\\METHODS\\RP-HPLC\\10-80A(210NM).MLast changed : 11/3/2015 4:03:43 PM by GTT(HPLC-09)Catalog No : HY-13736A Batch#18386 A-RP-141 Additional Info : Peak(s) manually integrated VWD1 A, Wavelength=210 nm (D:\\CHEM32\\DATA\\20151103\\20151103 2015-11-03 07-54-29\\001-2001.D)mAU1750150012501000750500250005101520min
===================================================================== Area Percent Report =====================================================================
Sorted By : Signal
Multiplier: : 1.0000Dilution: : 1.0000Use Multiplier & Dilution Factor with ISTDs
No peaks found
===================================================================== *** End of Report ***
Instrument 1 11/3/2015 4:22:50 PM GTT(HPLC-09)Page 1 of 1