Recordnumber

Data8 Dataflow type9

Description

01234567891011121314151617181920212223242526272829303132333435363738394041

1in2in3in4in5in6in7in8in9in10in11in12in13in14in15in16in17in18in19in20in21in22in23in24in25in26in27in28in29in30in31in32in33in34in35both36both37in38out

39out

40out

41out42outISee Section A.2RCurrent time

RCommunication intervalRBlade 1 pitch angle

RBelow-rated pitch angle set-pointRMinimum pitch angleRMaximum pitch angle

RMinimum pitch rate (most negative value allowed)RMaximum pitch rate

I0 = pitch position actuator, 1 = pitch rate actuatorRCurrent demanded pitch angleRCurrent demanded pitch rateRDemanded powerRMeasured shaft power

RMeasured electrical power outputROptimal mode gain

RMinimum generator speedROptimal mode maximum speed

RDemanded generator speed above ratedRMeasured generator speedRMeasured rotor speed

RDemanded generator torqueRMeasured generator torqueRMeasured yaw error

IStart of below-rated torque-speed look-up table =RINo. of points in torque-speed look-up table =NRHub wind speed

IPitch control: 0 = collective, 1 = individualIYaw control: 0 =

RBlade 1 root out of plane bending momentRBlade 2 root out of plane bending momentRBlade 3 root out of plane bending momentRBlade 2 pitch angleRBlade 3 pitch angleIGenerator contactor

IShaft brake status: 0=off, 1=Brake 1 onR

Nacelle angle from NorthRReservedRReservedRReserved

RDemanded yaw actuator torque

R

Demanded blade 1 individual pitch position or rate

424344454647484950515253545556575859606162636465666768697071727374757677787980818283848586

434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687outoutoutoutoutoutininininininoutoutoutoutoutinininininoutininininininoutininininininoutoutbothinininininin

RRRRRRIIIIRRII

RRR

RIIIIIRRRRRRRRRRRRRIIRRRRIIR

Demanded blade 2 individual pitch position or rateDemanded blade 3 individual pitch position or rateDemanded pitch angle (Collective pitch)Demanded pitch rate (Collective pitch)Demanded generator torqueDemanded nacelle yaw rate

Maximum no. of characters allowed in the “MESSAGE”No. of characters in the “INFILE” argumentNo. of characters in the “OUTNAME” argument

DLL interface version number (reserved for future use)Tower top fore-aft accelerationTower top side to side accelerationPitch overrideTorque overrideReservedReservedReserved

Rotor azimuth angleNo. of blades

Max. number of values which can be returned forRecord number for start of logging outputMax.

Number of variables returned for loggingReservedReservedReserved

Blade 1-3 root in plane bending momentBlade 1-3 root in plane bending momentBlade 1-3 root in plane bending momentGenerator start-up resistanceRotating hub My (GL co-ords)Rotating hub Mz (GL co-ords)Fixed hub My (GL co-ords)Fixed hub Mz (GL co-ords)Yaw bearing My (GL co-ords)Yaw bearing Mz (GL co-ords)Request for loads

1 = Variable slip current demand at position 81Variable slip current demandNacelle roll accelerationNacelle nodding accelerationNacelle yaw accelerationReservedReservedReserved

87888990919293949596979899100101102103104105

888990919293949596979899100101102103104105106ininininoutoutoutinininoutinininoutoutoutininIIRRRRRIIIIIIRIRRRRReservedReserved

Real time simulation time step

Real rime simulation time step multiplierMean wind speed incrementTurbulence intensity incrementWind direction incrementReservedReserved

Safety system number that has been activatedSafety system number to activateReservedReservedReserved

Yaw control flag

Yaw stiffness if record 102 = 1 or 3Yaw damping if record 102 = 2 or 3ReservedReserved

FINAL

Seenote(s)

111

233,5331,3

3343,53,54

181818

1019

13,2112,14

12,1412,14121213,2166

characters